Weight bands for gaseous and diesel generators by kW and padmount transformers by kVA, from Generac, Kohler, and Vantran documentation.
This is the exact table the Crane Cost Estimator runs on.
Cite it as: Antero Trail, "Generator and padmount transformer weights", anterotrail.com/tools/reference/generator-transformer-weights.
Primary sources are listed with each value and at the bottom of the page.
Operating weights for the generator_transformer_set crane scenario (PRP-CALC-2). Four band tables: residential air-cooled gaseous generators, commercial diesel gensets (radiator model, wet), three-phase pad-mount transformers, and single-phase pad-mount transformers. weight_high_lb is the heaviest documented unit at/under the band ceiling; the derivation layer adds a stated rigging allowance and does not interpolate within a band. Diesel gensets between two cited kW anchors are sized by an explicitly-labeled linear heuristic (see derivation spec), mirroring the telehandler-interpolation precedent in crane_roofing.py. A rating outside all bands returns no match and the scenario asks for a known weight.
Access date for citations: 2026-07-12.
generator gaseous bands
band ID
KW min
KW max
weight high LB
Source
gaseous_le_26kw
0
26
518
GENERAC
GENERAC. 26 kW Guardian Series Residential Standby Generator, model G007290-0 - Product Spec Sheet, Specifications table: Unit weight 518 lb / 235 kg (www.generac.com)
generator diesel anchors
KW
weight LB
Source
100
2,468
KOHLER
150
3,090
KOHLER
1,000
17,821
KOHLER
1,300
31,000
KOHLER
2,000
35,000
KOHLER
KOHLER. 100REOZJF diesel genset, G5-357 - Dimensions and Weights: weight (radiator model), wet 1119 kg (2468 lb) (resources.kohler.com)
KOHLER. 150REOZJF diesel genset, G5-371 - weight (radiator model), wet 1295-1402 kg (2855-3090 lb); high end used (resources.kohler.com)
Transformer weights are from a single manufacturer's cut-sheet (Vantran). Pad-mount weight varies materially by voltage class, copper vs. aluminum windings, and cooling - flagged on output; verify against the actual nameplate before final sizing.
These calculators produce planning estimates from published public rate
schedules. They are not a formal quote. Confirm equipment, access, and
pricing with a licensed operator or rental yard before you rely on any
number for an estimate.